top of page
Search

Pentair Pool School: Owner Reference Guide

Danny McCue
4 days ago
4 min read

Use this page after your Pool School visit to revisit how to operate and care for your pool. Exact settings and maintenance procedures depend on your installed models and plumbing. Your equipment labels and manuals, plus the instructions recorded at your Pool School, take priority.

For a printable copy, download the Pool School Owner Reference PDF.


Pool and Spa Modes

Pool mode circulates water through the pool for normal filtration. On a shared pool and spa system, Spa mode moves the valves so water circulates through the spa and lets the heater serve it. Select one mode and allow the valves to finish moving before changing settings. When spa use is finished, return to Pool mode. Your installed system may be configured differently, so follow the labels shown during Pool School.


Auxiliary Pump Functions and Settings

Auxiliary pumps may operate a cleaner, waterfall, water feature, or other dedicated equipment. Use the named IntelliCenter feature or schedule assigned to that pump. Some auxiliary pumps require the main circulation pump to run first. Confirm the correct sequence for your installation. Never run a pump without water flow; stop it and call for service if it runs dry, makes unusual noise, or does not move water.


Valve Operation and Settings

Valves direct water between the pool, spa, heater, and water features. In normal operation, leave automated valves in their labeled automatic position and use IntelliCenter to change modes. Do not force a handle or turn a valve while its actuator is moving. If a valve must be moved manually, shut off the pump first and follow the marked positions reviewed for your pool.


IntelliCenter and Breakers

Use the IntelliCenter home screen to select Pool, Spa, Features, lighting, schedules, and temperature. Return the system to its normal automatic operating mode after a temporary change. Breakers protect and isolate equipment; they are not everyday pump controls. Know the labeled breaker for the pool equipment. If it trips, do not keep resetting it or open the electrical panel. Call a qualified service professional if it trips again.


Electronic Actuators

Actuators automatically turn valves when Pool, Spa, or a feature is selected. IntelliCenter assigns each actuator to a valve and changes its position with the selected circuit. If a feature starts but water does not route correctly, stop the feature and check for a system alert or a valve that did not move. Do not adjust wiring, switches, or travel limits unless qualified.


IntelliVibe or MicroBrite Lighting

Use the lighting circuit or control assigned to your installed IntelliVibe controller or MicroBrite lights. IntelliCenter may provide on and off, color, or feature controls depending on the setup. Use the control method demonstrated at Pool School. Keep pool lights off before service; underwater fixtures and wiring should only be opened or repaired by a qualified pool professional.


Filter Gauge and Maintenance

After the filter is cleaned, run the system and record the clean starting pressure. Check it weekly. For this pool, plan to inspect and clean about every four months or when pressure rises about 10 psi above the clean baseline, whichever comes first; follow the exact filter manual if it gives a different trigger. Before opening a pressurized filter, turn off the pump, open the air relief, and wait until the gauge reads zero. Never loosen a clamp under pressure.


Heater Operation and Maintenance

Choose Pool or Spa mode, then set the desired temperature in IntelliCenter. The heater needs proper water flow and heats only when the system calls for it. If it does not fire, check the selected mode, setpoint, pump flow, and displayed error. Keep the heater intake and exhaust area clear. Do not remove heater panels, change gas settings, or repeatedly reset an error; call for service if the alert returns.


Freeze Plugs and Proper Shutdown

Automatic freeze protection depends on the controller having power and the circulation system operating as configured. Know where your specific equipment drain or freeze plugs are, but do not remove them as a substitute for freeze protection. If the pool must be shut down or winterized, follow the pool-specific procedure reviewed by your builder or service professional. Water left in equipment or plumbing can freeze and cause damage.


Autofill Operation and Maintenance

The autofill maintains the pool near its set water level; a normal pool level is generally around the middle of the skimmer opening. Check that the level is steady and the fill is not running continuously. A stuck float, leak, or unusually high level can waste water or dilute pool chemistry. If it keeps filling or overfills, close its labeled water supply valve if you can do so safely and contact your pool professional.


Pool Sanitation System

Your installed sanitation equipment helps maintain the pool's disinfectant level. Learn its name, normal indicator lights, and where the output setting is displayed. Test the actual pool water regularly; a controller or generator display does not replace a water test. Salt systems need circulation and the model's required salt level. Do not clean a cell or change sanitizer settings without following that unit's manual and the instructions reviewed at Pool School.


Basic Pool Chemistry

Test before adjusting. Common reference ranges in Pentair residential guidance include pH 7.2-7.8, total alkalinity 80-120 ppm, and calcium hardness about 200-400 ppm. Chlorine and stabilizer targets depend on the sanitation system and pool finish. CDC advises at least 2 ppm free chlorine when cyanuric acid (stabilizer) is used. Stabilizer helps protect chlorine from sunlight, but excess can reduce chlorine effectiveness. Follow the target for your installed system and finish.


Brushing Technique and Schedule

Use a brush suitable for your pool finish. Work from the waterline down, brushing walls, steps, benches, corners, and areas behind ladders or fittings where circulation may be weaker. Brush at least weekly and after heavy debris, storms, or algae treatment. New plaster or other new finishes may need a more frequent startup schedule; follow the finish manufacturer's and builder's startup instructions for your specific pool.


Chemical Safety

Never mix chlorine products with acid or with each other. Keep chemicals in their original labeled containers, separated and secured from children and pets. Follow each label and use protective equipment as directed.

Pentair and Health References


Pentair Warranty Service

Submit a warranty request at dreamlifepools.com/warranty-service. After you submit the form, the Pentair Service Center should notify you within 72 hours with further information. When the form asks for your pool start-up date, enter the date of your Pool School.

 
 
 

Comments


Thin blue line flag
homes for heros logo
Marine Corp veteran logo
camp hope logo

We Proudly Support

DreamLife Custom Pools Logo
Disabled American Veterans logo
support firefighters flag
Tunnels to Towers foundation logo

DreamLife Custom Pools

Info@dreamlifecustompools.com

10871 Ruger Rd Willis Tx 77378

© 2023 by Dream Life Custom Pools. All rights reserved.